Tuesday, March 8, 2011

8 foot light fixture upgrade

Recently we had a commercial lighting upgrade project in Boise, Idaho where the customer had 8' T12 fixtures that each had 4 light bulbs in them.  They were big fixtures that looked very dated and they were not very energy efficient.    Each fixture was consuming 276 watts and not producing adequate light.

We looked at a couple of different options and decided that it was not worth it to attempt to retrofit the old fixture to something more energy efficient like T8 8' lamps.  

The better approach was to scrap the old fixture entirely and use a new 8' fixture with tandem 4' T8 light bulbs.  The 4' T8 bulbs last longer than the 8' lamps and are much more energy efficient.  

We used high performance ballasts and high lumen T8 light bulbs.  The new fixtures use 110 watts and produce more light than the old fixtures.  

Also the light quality is better.  The old 8' T12 bulbs had a color rendering index of only 60, while the new T8 4' bulbs have a CRI of 83. 

The old T12 8' light bulbs only had a rated life time of 12,000 hours, while the new high performance T8 light bulbs have a rated life of 24,000 hours.

By using the energy saving fixtures and high performance bulbs and ballasts we were able to get the customer Idaho Power rebates that paid for approximately 70 percent of total project costs. 

The energy savings on each fixture is estimated at approximately $37 per year.   The energy savings in the first year is more than the after rebate cost of each fixture.  

Bright Ideas Lighting Co also warrantied all the bulbs and ballasts on this job for 2 years, thus eliminating lighting maintenance costs!

It is important when doing commercial lighting projects like this to make use you use a licensed electrical contractor who has experience in lighting upgrades.   

Sunday, January 30, 2011

LED T8 light tubes

We at Bright Ideas Lighting Co recently did a commercial lighting upgrade at a building in downtown Boise, Idaho.  The job qualified for rebates from Idaho Power and was run through the custom efficiency program at Idaho Power, which pays rebates of 12 cents per kilowatt hour saved.

This project was the first time that we have used the new T8 LED lighting tubes.  We have been skeptical of these in the past, based on their price and relatively minor improvements over high efficiency T8 fluorescent lights.  However, in this situation the lights in question were over 45 feet in the air and the only way to get to the lights was by building an expensive scaffolding.   The T8 light tubes that we purchased were rated at 60,000 hours, which is significantly longer than even the T8 extra long life bulbs.  

Below is the picture of the lights before any retrofit was done.  The height of the lights made maintenance very difficult.  Maintenance on the bulbs had not been done in several years due to the cost of the scaffolding build.
T12 fluorescent
The bulbs before the lighting retrofit were T12 "cool white" color.   The owner of the building wanted to brighten up the look and decided to go with a higher kelvin 5500K lights. 

Even though the LED tubes were significantly more expensive than just a simple T12 to T8 lighting retrofit, we felt that in this case the extra cost of the LED tubes was justified. 


LED tube lights




These lights were at a location that was simply not accessable by use of a scissor lift.   The only way to get to the lights was through scaffolding build, at a cost of thousands of dollars, and a large disruption to clients.

Before the lighting retrofit there were no lighting controls on these lights and they ran 24/7.   We have now added a lighting control that turns off the lights in evenings and weekends.  This will significantly cutdown the overall run time of the lights. 

With the LED tube lights and the addition of the time clock controlling the lighting hours we believe it will be several years before the scaffolding build needs to be done again.  

Stay tuned for more information on this project as it will be featured on Idaho Power's "success stories" page, where Idaho Power recognizes outstanding lighting retrofit projects.

Wednesday, November 17, 2010

Free lighting retrofits

We at Bright Ideas Lighting Co have recently heard of companies in Idaho doing lighting retrofits at no net cost to the customer-  the "free" lighting retrofit.

How are these companies able to do a lighting retrofit completely free to the customer?  Generally under normal circumstances the Idaho Power lighting rebates will pay for about 50% of a job, with customer paying for the remainder.

How do these companies get the rebates to pay for 100% of the lighting retrofit job?  The biggest thing that we have seen is excessive delamping.  Idaho Power pays $12 per delamp.  So if the fixture goes from 4 lamp t12 to 2 lamp T8 the delamping portion of the rebate is $24 (2x12).  The 4-2 lighting retrofit is very common and generally looks good.  What we have seen is the retrofit going from 4 lamp T12 to 1 lamp T8.   This looks terrible, where there is only one light bulb in a fixture designed to have four.  The light levels are actually far lower after the retrofit.  However, with the 3 delamps, plus the retrofit incentives the Idaho Power rebates literally cover all of the costs.   Other similar types of work are delamping 2 lamp fixtures to 1 lamp fixtures.


We are not going to do lighting retrofits where the end result is that the lighting looks worse than before the lighting retrofit!  The point of a lighting upgrade is to get more energy efficient lighting and have the lighting look better than before the lighting retrofit.   No point in doing a lighting upgrade if the end results is big energy savings, but lighting that looks bad.
 
Other things that we see done by the companies offering "free" lighting retrofits include using non licensed electricians, and using poor quality lamps and ballasts.  Do you really want your lighting and electrical work done by non-licensed, non-insured workers?   Do you want the light bulbs and ballasts to have a brand name that you have never even heard of?

At Bright Ideas Lighting Co we are always going to use 800 series high performance light bulbs and NEMA premium ballasts in all of our lighting retrofits. 

One thing that from what we have seen is almost always a part of the "free" lighting retrofit is improper disposal of the old T12 fluorescent light bulbs.  The old fluorescent light bulbs contain mercury and need to be recycled.  Recycling cost money and from what we have seen is that many of the "free" retrofitters just throw all of their old mercury containing tubes in the trash.  At Bright Ideas Lighting Co we recycle all old fluorescent tubes and can provide written certificate of recycling from our recycling company.

So with lighting retrofits, just as in most things in life, there is no free lunch.  Our retrofits are not going to be free, but we will offer free estimates and consultation on lighting retrofits.

Monday, September 6, 2010

Retrofit kits

Bright Ideas Lighting Co recently did a project using Lithonia RT8 retrofit kits.  The RT8 kits completely changed the look of the office space and reduced energy costs by over 50%.   The great thing about these kits is that they cost less than an entire new fixture (both in labor and product costs), however the end result looks like a new fixture!!

The previous lighting were old 4 lamp T12 acrylic troffers.  Many of the bulbs were not even matching colors.  Also many of the fixture covers were very dirty.   The old electromagnetic T12 ballasts were also very noise, besides being very energy inefficient.   Each fixture is using approximately 155 watts.

 The picture to the right after we had installed the Lithonia RT8 lighting retrofit kits.

Notice the cleaner more modern look.  The new kits with the 2 lamp T8 electronic high performance ballast are only using 54 watts per fixture.  Note -The before and after pictures are not of the same room, but are of the same job.  Just could not get into same room for the "after" shot.

Because we were retrofitting from T12 to T8 and delamping from 4 lamps to 2 lamps the customer was able to get a $38 per fixture rebate from Idaho PowerBright Ideas Lighting Co filled out all of the Idaho Power paper work for the customer and made the process very easy.   The customer was able to get what looks like brand new fixtures at a fraction of the cost by using the Lithonia RT8 retrofit kits.

Wednesday, August 25, 2010

HID lighting upgrades

Does your building have light fixtures that look like the one below?

Metal halide fixture
If your building has light fixtures that look like the above fixture you are paying twice as much in energy cost as you should be paying.   The light fixtures like in the picture above are high intensity discharge - metal halide, high pressure sodium, or mercury vapor.  

Bright Ideas Lighting Co. recommends removing these old fixtures and installing new highbay fluorescent fixtures.  Typically the energy savings is 50%.   The most common type of fixture like the one pictured above is a 400 watt metal halide.   These typically take about 5 minutes to come to full brightness.  The ballasts on these fixtures typically have an audible humming noise.  

The 400 watt fixtures can easily be replaced by either 4 lamp T5 HO fixtures or 6 lamp T8s.  If your business is in Idaho, the Idaho Power rebates are $90 for the T5 HO fixture and $120 for the 6 lamp T8.  Since the cost of the two fixtures is approximately the same most projects are going with the 6 lamp T8 high bay fixtures. 

The fluorescent fixtures come up to full brightness quickly,  almost instantaneously, so you can turn them off and on without having to put up with the 5 minute warmup time for HID fixtures.  Also the fluorescent fixtures can  have occupancy sensors attached so that the fixture will partially turn off when there is no one nearby.

At Bright Ideas Lighting Co we just completed a project where we replaced almost 100 of the 400 watt metal halide lights with 6 lamp T8 and getting a tremendous energy savings and Idaho Power rebate for the customer.

Tuesday, July 27, 2010

Boise lighting repair

Call Bright Ideas Lighting Co for lighting repair in Boise, Nampa, Caldwell, Meridian, Eagle and Kuna Idaho.  We handle all interior and exterior lighting repair.   Ballast changeouts, lighting retrofits, hard to reach lights. We have a bucket truck and are able to change pole lights up to 50' high.

Monday, June 28, 2010

T12 electromagnetic ballast phaseout

Per the Energy Policy Act of 2005 as of July 1, 2010 electromagnetic T12 ballasts will no longer be allowed to be imported to or manufactured in the United States. 

Suppliers are allowed to sell their remaining inventory of the electromagnetic T12 ballasts.  However, in practical terms most suppliers have stopped selling the electromagnetic ballasts months ago.  

This is the first phase of the T12 fluorescent phaseout.  In July of 2012 the T12 bulbs will also phased out similar to the ballast.  This is part government regulations to force energy efficiency.   T8 fluorescent lights are approximately 30% more energy efficient than T12 lights, plus the T8 lights provide much higher color rendering (better light quality). 

A significant portion of businesses have already did the lighting conversion, but even today T12 light bulb sales make up over 20% of all fluorescent tube sales.   If you don't know what your business has, please give Bright Ideas Lighting Co a call at 208-378-1889 to schedule a free lighting consultation.  We service lighting in Boise, Nampa, Meridian, Eagle, Kuna, Caldwell, and Mountain Home, Idaho.   We service the entire Treasure Valley.

Ultimately if your home or business still has the T12 fluorescent light bulbs you need to consider retrofitting to T8 fluorescents.  This be done by changing bulbs and the ballast in your current fixture, so there is no need to change the entire fixture.  There are currently Idaho Power rebates available for businesses who convert their lights from T12 to T8.   At Bright Ideas Lighting Co. we are experts in all types of lighting retrofits whether T12 to T8, HID to fluorescent, or induction or LED retrofits.